Référence pièce
Vous pouvez trouver ici le numéro
de référence lié au produit recherché.
Compact Vacuum Regulator ITV009□ Series external appearance
Model | ITV009□ | ||
---|---|---|---|
Minimum Supply Pressure | Set pressure -1 kPa | ||
Maximum Supply Pressure | -101 kPa | ||
Set Pressure Range | -1 to -100 kPa | ||
Power Supply | Voltage | 24 V DC ±10%, 12 to 15 V DC | |
Current Consumption | Power supply voltage 24 V DC type: 0.12 A or less Power supply voltage 12 to 15 V DC type: 0.18 A or less | ||
Input Signal | Voltage Type | 0 to 5 V DC, 0 to 10 V DC | |
Current Type | 4 to 20 mA DC, 0 to 20 mA DC (sink type) | ||
Input Impedance | Voltage Type | Approx. 10 k Ω | |
Current Type | Approx. 250 Ω | ||
Output Signal Note 4: | Analog Output | 1 to 5 V DC (output impedance: approx. 1 kΩ) Output accuracy ±6% F.S. or less | |
Linearity | ±1% F.S. or less | ||
Hysteresis | 0.5% F.S. or less | ||
Repeatability | ±0.5% F.S. or less | ||
Sensitivity | 0.2% F.S. or less | ||
Temperature Characteristics | ±0.12% F.S. / °C or less | ||
Operating Temperature Range | 0 to 50°C (no condensation) | ||
Enclosure | IP65 equivalent * | ||
Connection Type | Built-in one-touch fittings | ||
Connection Size | For Single Unit | Metric Size | [1], [2], [3]: ø4 mm |
Inch Size | [1], [2], [3]: ø5/32" | ||
Manifold | Metric Size | [1], [3]: ø6 mm, [2]: ø4 mm | |
Inch Size | [1], [3]: ø1/4", [2]: ø5/32" | ||
Weight Note 1: | 100 g or less (without options) |
Note 1: Indicates the weight of a single unit.
For IITV00-n,
Total weight (g) ≤ number of stations (n) ×; 100 + 130 (weight of end block A and B assemblies) + DIN rail weight (g).
Note 2: When there is a downstream flow consumption, the pressure may become unstable depending on the tubing conditions.
Note 3: While the power is on, the solenoid valve may make noise when operating. This noise is normal and does not indicate a fault.
Note 4: When measuring ITV analog output from 1 to 5 V DC, if the load impedance is less than 100 kΩ, the analog monitor output accuracy of ±6% F.S. or less may not be achievable. If an accuracy within ±6% is required, contact the manufacturer for further assistance. Output pressure remains unaffected.
*When using under conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use.
(Refer to the manufacturer's catalog for details.)
When the input signal rises, the vacuum pressure solenoid valve (1) turns ON. Due to this, part of the vacuum pressure (VAC.) supply passes through the vacuum pressure solenoid valve (1) and becomes vacuum pressure. This vacuum pressure feeds back to the control circuit (4) via the pressure sensor (3). Here, pressure corrections continue through alternate operation of the vacuum pressure solenoid valve and atmospheric pressure solenoid valve until the vacuum pressure becomes proportional to the input signal, thus supplying vacuum pressure that is consistently proportional to the input signal.
Operating principle drawing
Block diagram
(Unit: mm)
Single unit dimensional drawing 1
Single unit dimensional drawing 2
Single unit dimensional drawing 3
Single unit dimensional drawing 4
Port Positions
No. | [1] | [2] | [3] |
---|---|---|---|
ITV009□ | VAC | OUT | ATM |
Note: When using under conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use. (Refer to the manufacturer's catalog for details.)
Single unit for manifold dimensional drawing
Linearity and hysteresis graph
Repeatability graph (at 50% of signal input)
Référence pièce
|
---|
ITV0090-2UBL |
ITV0090-2UL |
ITV0090-3UBL |
ITV0090-3UBN |
ITV0090-3US |
Référence pièce | Relatif à |
Prix unitaire standard
| Quantité minimale de commande | Remise sur volume | Côté alimentation, diamètre de tube de connexion | Côté commande, diamètre de tube de connexion | Signal d'entrée | Spécifications de tuyauterie | Connecteur de câble | Support | Tension d'alimentation électrique | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 318.18 € | 1 | 26 jours | Ø5/32" | Ø5/32" | 0 à 5VDC | Pour unité simple | Type à angle droit 2m | Support plat | 24VDC | ||
- | 315.74 € | 1 | 26 jours | Ø5/32" | Ø5/32" | 0 à 5VDC | Pour unité simple | Type à angle droit 2m | Sans support | 24VDC | ||
- | 318.18 € | 1 | 26 jours | Ø5/32" | Ø5/32" | 0 à 10VDC | Pour unité simple | Type à angle droit 2m | Support plat | 24VDC | ||
- | 297.85 € | 1 | 26 jours | Ø5/32" | Ø5/32" | 0 à 10VDC | Pour unité simple | Sans connecteur de câble | Support plat | 24VDC | ||
- | 315.74 € | 1 | 26 jours | Ø5/32" | Ø5/32" | 0 à 10VDC | Pour unité simple | Type droit 3 m | Sans support | 24VDC |
Loading...
Type | Régulateur de vide électronique | Méthode de contrôle | Pilote interne | Forme | Standard |
---|---|---|---|---|---|
Côté alimentation, type de connexion | Tuyau à simple effet | Côté commande, types de connexions | Tuyau à simple effet | Plage de pression de réglage(kPa) | -1::-100 |
Configurer
Propriétés de base
Côté commande, diamètre de tube de connexion
Signal d'entrée
Spécifications de tuyauterie
Connecteur de câble
Support
Tension d'alimentation électrique
Type
Côté alimentation, diamètre de tube de connexion
Filtrer par type de données CAO
Filtrer par jours d'expédition standard
Propriétés optionnelles