VT317, Distributeur 3 / 2 à clapet à commande directe, Tous modèles

VT317, Distributeur 3 / 2 à clapet à commande directe, Tous modèles
SMC Solenoid Valve.
[Features]
· Compact yet with a large valve capacity
· Suitable for use in vacuum applications
· 6 valve functions in 1 valve

(i)Remarque

  • Product images may be representative. Refer to the manufacturer's catalog for details.

Référence pièce

Vous pouvez trouver ici le numéro
de référence lié au produit recherché.

3-Port Solenoid Valve, Direct Operated Poppet Type, Rubber Seal, VT317 Series Specifications

VT317 Series, rubber seal external appearance

VT317 Series, rubber seal external appearance

VT317 Series Rubber Seal JIS symbol

VT317 Series Rubber Seal JIS symbol

Surge voltage suppressor mounting part (for G)

Surge voltage suppressor mounting part (for G)

Switching Method Direct operation type 2-position single solenoid
Usable Fluids Air
Operating Pressure Range 0 to 0.9 MPa
Ambient Temperature and Operating Fluid Temperature -10 to +50°C (no freezing.)
Response time*1 30 ms or less (at 0.5 MPa)
Maximum Operating Frequency 10 Hz
Lubrication Not required (Use turbine oil class 1 ISO VG32, if lubricated)
Manual Operation Non-locking, push type
Mounting Orientation Free
Impact resistance / Vibration resistance*2 150/50 m/s2
Enclosure Dust-proof
Electrical Entry Grommet, conduit
Conduit terminal, DIN terminal
Coil rated voltage (V) AC (50/60 Hz) 100, 200, 110, 220, 240
DC 24, 12
Allowable Voltage Fluctuation -15% to +10% of rated voltage
Apparent power*3 AC Starting 19 VA (50 Hz), 16 VA (60 Hz)
Holding 11 VA (50 Hz), 7 VA (60 Hz)
Power consumption*3 DC Without indicator light: 6 W, With indicator light: 6.3 W
Light and Surge Voltage Suppressor
(Not available for the grommet type.)
AC Varistor, neon bulb
DC Varistor, LED: 100 V or more is neon bulb

*1: Based on JIS B 8419:2010 dynamic performance test. (Coil temperature of 20°C, at rated voltage, with no surge voltage suppressor)
*2: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunction occurred in 1 sweep test between 45 and 1,000 Hz. The test was performed in both energized and de-energized states in the axial and right angle directions of the main valve/armature. (Initial value)
*3: When rated voltage is applied.

Flow Rate Characteristics / Weight Table

Valve type Flow Rate Characteristics Weight
1→2 (P→A) 2→3 (A→R) 3→2 (R→A) 2→1 (A→P)
C
(dm3/(s·bar))
b Cv C
(dm3/(s·bar))
b Cv C
(dm3/(s·bar))
b Cv C
(dm3/(s·bar))
b Cv Grommet
VT317 2.4 0.26 0.62 2.6 0.34 0.67 2.8 0.25 0.67 2.5 0.37 0.66 0.29 kg
VT317V
(Vacuum specification)
VT317E
(Continuous duty type)

*Value for valve single unit. This will differ for the manifold. See manifold specifications in the manufacturer's catalog for details.

Structure Drawing

Structure drawing when not energized

Structure drawing when not energized

The spool valve (2) is pushed upward with the reaction force of the spring (3), sealing port (P) while port (A) and port (R) are opened.

Structure drawing when energized

Structure drawing when energized

The armature assembly (5) is attracted to the fixed core (6), pushing down the spool valve (2) with the push rod (7). As a result, port (R) is sealed while port (P) and port (A) are opened. At this time, a gap is formed between the armature assembly (5) and the fixed core (6), but the magnetic attraction of the coil overcomes the spring force inside the armature assembly (5), causing the armature assembly (5) to be pulled into close contact with the fixed core (6).

Number Part name Material Note
1 Body Die-cast aluminum Platinum silver coated
2 Spool Valve Aluminum, NBR -

Outline dimensional drawing

 

(Unit: mm)

 

Grommet: VT317-□G dimensional drawing

Grommet: VT317-□G dimensional drawing

*Lead wire length 600 mm (VT317-□H) also available.

 

(Unit: mm)

 

Conduit: VT317-□C dimensional drawings

Conduit: VT317-□C dimensional drawings

 

(Unit: mm)

 

Conduit terminal: VT317-□T dimensional drawings

Conduit terminal: VT317-□T dimensional drawings

 

(Unit: mm)

 

DIN terminal: VT317-□D dimensional drawings

DIN terminal: VT317-□D dimensional drawings

VT317 Series Manifold Specifications

VT317 type manifold external appearance

VT317 type manifold external appearance

*Pictures show representational models. This product is the valve unit only. The manifold is not included.

Manifold specifications

  • Manifold type: B mount
  • Maximum number of valve stations: 20 *1
  • Compatible solenoid valve model: VO317□-□□□(-Q) *2
  • *1When there are 3 stations or more, apply pressure from both sides of the P port. Also, in the case of a common exhaust type, exhaust from both sides of the R port.
  • *2Can also be mounted to VVT320 Series manifolds.
Exhaust port Connecting part (direction) / Port size
Symbol Format P A R
1 Common* Base (side) Base (side) Base (side)
1/4 (3/8) 1/4 1/4 (3/8)
3 Standalone Base (side) Base (side) Base (side)
1/4 1/4 1/4

*In the case of the common exhaust type, The P and R ports can be made 3/8 by mounting an attachment.

Flow Rate Characteristics / Weight Table

Valve type Flow Rate Characteristics Weight
1→2 (P→A) 2→3 (A→R) 3→2 (R→A) 2→1 (A→P)
C
(dm3/(s·bar))
b Cv C
(dm3/(s·bar))
b Cv C
(dm3/(s·bar))
b Cv C
(dm3/(s·bar))
b Cv Grommet
VO317 2.0 0.11 0.47 2.2 0.12 0.49 2.0 0.14 0.45 2.1 0.14 0.48 0.32 kg
VO317V
(Vacuum specification)
VO317E
(Continuous duty type)

Precautions

  • *1The bottom of the solenoid valve has a breather hole for the main valve. Take proper measures to prevent this hole from being blocked as this will lead to a malfunction. *Ordinarily, when the solenoid valve is mounted on a metal surface, it can breathe through the breather hole via the breather groove. However, if the surface on which it will be mounted is made of rubber, the rubber could deform and block the hole.
  • *2Take proper measures to prevent dust and foreign matter from entering through unused ports, such as the exhaust port. The grommet portion contains a breather hole for the armature. Take proper measures to prevent dust or foreign matter from accumulating in this area.

Manifold specification specific product precautions

  • *When mounting the valve on the manifold base, the mounting orientation is set. Mounting in the wrong direction may cause connected equipment to malfunction. When mounting, see the manufacturer's catalog regarding how to switch from a N.C. specification → N.O. specification.
  • *Each valve is fixed to the manifold base with two M4 mounting screws. Tighten the screws sufficiently when re-mounting.
    Mounting screw tightening torque: 1.4 N⋅m
  • *When mounting, tighten the M4 or equivalent screws evenly into the mounting holes of the manifold base.

Other

*See the manufacturer's catalog for information other than that above.

Référence pièce
VO317-5D-Q
VO317-5DZ-Q
VO317E-5D-Q
VO317E-5DZ-Q
VO317V-5D-Q
VO317V-5DS-Q
VO317V-5DZ-Q
VT317-5D-02-Q
VT317-5D-02F-Q
VT317-5DZ-02-Q
VT317-5DZ-02F-Q
VT317-5DZ-02N-Q
VT317E-5DS-02F
VT317E-5DZ-02-Q
VT317E-5DZ-02F-Q
VT317E-5DZ-02N-Q
VT317V-5D-02-Q
VT317V-5D-02F-Q
VT317V-5DZ-02-Q
VT317V-5DZ-02F-Q
VT317V-5DZ-02N-Q
Référence pièce
Prix unitaire standard
Quantité minimale de commandeRemise sur volume
Jour
d'expédition standard
?
Application Sens du montage Caractéristiques Type à commutation Tension Type à port de tuyau Filetage nominal de tuyauterie Tuyauterie Valeur CV Alimentation en air piloté Témoin / Suppresseur de surtension Conformité CE Options de vanne

55.31 €

1 26 jours Unité de montage du collecteurBase de collecteurStandard2 positions, normalement ouvert24VDC--Tuyauterie de fondation0.47InterneAucunProduit conforme CEType standard

60.69 €

1 26 jours Unité de montage du collecteurBase de collecteurStandard2 positions, normalement ouvert24VDC--Tuyauterie de fondation0.47 ~ 0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType standard

65.85 €

1 26 jours Unité de montage du collecteurBase de collecteurStandard2 positions, normalement ouvert24VDC--Tuyauterie de fondation0.47InterneAucunProduit conforme CEType à utilisation continue

71.23 €

1 16 jours Unité de montage du collecteurBase de collecteurStandard2 positions, normalement ouvert24VDC--Tuyauterie de fondation0.47 ~ 0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType à utilisation continue

57.34 €

1 4 jours Unité de montage du collecteurBase de collecteurStandard2 positions, normalement ouvert24VDC--Tuyauterie de fondation0.47 ~ 0.62InterneAucunProduit conforme CESpécification de vide

59.24 €

1 26 jours Unité de montage du collecteurBase de collecteurStandard2 positions, normalement ouvert24VDC--Tuyauterie de fondation0.47InterneAvec suppresseur de surtensionProduit conforme CESpécification de vide

62.73 €

1 26 jours Unité de montage du collecteurBase de collecteurStandard2 positions, normalement ouvert24VDC--Tuyauterie de fondation0.47InterneAvec témoin et suppresseur de surtensionProduit conforme CESpécification de vide

55.31 €

1 39 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDC[Rc (R)] Rc1/4Tuyauterie directe0.62InterneAucunProduit conforme CEType standard

55.31 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCG1/4Tuyauterie directe0.62InterneAucunProduit conforme CEType standard

60.69 €

1 4 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDC[Rc (R)] Rc1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType standard

60.69 €

1 4 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCG1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType standard

60.69 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCNPT1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType standard

67.74 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCG1/4Tuyauterie directe0.62InterneAvec suppresseur de surtensionAucunType à utilisation continue

71.23 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDC[Rc (R)] Rc1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType à utilisation continue

71.23 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCG1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType à utilisation continue

71.23 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCNPT1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CEType à utilisation continue

57.34 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDC[Rc (R)] Rc1/4Tuyauterie directe0.62InterneAucunProduit conforme CESpécification de vide

57.34 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCG1/4Tuyauterie directe0.62InterneAucunProduit conforme CESpécification de vide

62.66 €

1 4 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDC[Rc (R)] Rc1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CESpécification de vide

62.73 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCG1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CESpécification de vide

62.73 €

1 26 jours Utilisation uniqueDirectStandard2 positions, normalement ouvert24VDCNPT1/4Tuyauterie directe0.62InterneAvec témoin et suppresseur de surtensionProduit conforme CESpécification de vide

Loading...

  1. 1

Informations de base

Type Électrovannes Nombre de ports Vanne à 3 ports Nombre de solénoïdes Simple
État à la mise hors tension Reprise automatique (retour de ressort) Type d'entraînement Clapet à mouvement linéaire Type de joint Joint souple
Pression nominale(MPa) 0 à 0,9 Interrupteur manuel Non fourni Entrée électrique du fil de sortie Borne DIN