Model | Port size | Sonic conductance dm3/(s·bar) | Critical pressure ratio | Weight (g) |
---|---|---|---|---|
ASN2-M5 | M5 ×; 0.8 | 0.36 | 0.15 | 5 |
ASN2-U10/32 | 10-32UNF | 0.36 | 5 | |
ASN2-01 | 1/8 | 0.72 | 0.35 | 17 |
ASN2-02 | 1/4 | 1.3 | 34 | |
ASN2-03 | 3/8 | 3.32 | 55 | |
ASN2-04 | 1/2 | 4.9 | 107 |
ASN2 Series Structural Drawing
Number | Description | Material | Note |
---|---|---|---|
1 | Handle | PBT | - |
2 | Needle | Brass | Electroless nickel plated |
3 | Lock nut | Steel*2 | Zinc chromate*1 |
4 | Needle guide | Brass | Electroless nickel plated |
5 | Washer | Carbon steel | Nickel plated |
6 | O-ring | NBR | - |
7 | Silencer | PVA sponge | - |
8 | Silencer cover | Soft polyethylene | - |
9 | Body B | Brass | Electroless nickel plated |
10 | Gasket | NBR / stainless steel | M5, U10/32 only |
*1: The round lock nut is electroless nickel plated.
*2: The round lock nut is made of brass. However, made of steel for ASN2-□01 and □02 only.
(Units: mm)
ASN2 Series dimensional drawing
Model | Screw D | øD | L1*2 | H | |
---|---|---|---|---|---|
Min | Max | ||||
ASN2-M5 | M5 ×; 0.8 | 10 | 20.5 | 23.3 | 8 |
ASN2-U10/32 | 10-32UNF | 10 | 20.5 | 23.3 | 8 |
ASN2-01 | 1/8 | 15 | 29.1 | 34.1 | 12 (12.7) |
ASN2-02 | 1/4 | 20 | 33.7 | 38.7 | 17 (17.5) |
ASN2-03 | 3/8 | 25 | 35.9 | 40.9 | 19 |
ASN2-04 | 1/2 | 30 | 48.1 | 53.1 | 24 (23.8) |
*1: Values enclosed in parenthesis ( ) are dimensions of NPT screw specifications.
*2: L1 values are reference dimensions.
Examples of inapplicable circuits
Inapplicable circuit example (Perfect valves: VF66□□, VS7-6-FPG, VS7-8-FPG)
*Residual pressure behind the exhaust needle may cause check valve malfunction in the perfect valve.
Inapplicable circuit example 2 (circuit with pilot check valve between actuator and solenoid valve)
*Residual pressure behind the exhaust needle may cause pilot check valve malfunction.
Example of interference with fittings
*If mounting to connection ports of solenoid valves, interference may occur with the fittings. Consult the catalog before installing.
[Features]
· Superior noise reduction
Reduces noise at maximum flow rate by 20 dB or more
· Easy cylinder speed control
Features the same needle shape as the speed controller