Référence fabricant: GP46-10-01ML5-Q
Marque: SMC
Prix: 55.68 €
Délai de livraison: 26 jours
Maximum Indicated Pressure: 1,0 MPa
Connection screw: R 1⁄8
Option: Avec M5 (filetage femelle)
Special Specification: Marquage CE
Indication lamp addition symbol: Diode électroluminescente / 24VDC
Référence pièce
Vous pouvez trouver ici le numéro
de référence lié au produit recherché.
GP46-10-01ML5-Q
Pressure Gauge With Switch GP46 external appearance
Circuit example
Model | GP46 | ||
---|---|---|---|
Pressure gauge | Shape | Back side thread | |
Ambient and fluid temperature | -5 to +60°C (no freezing) | ||
Indicated pressure range | 0 to 1.0 MPa | ||
Port size*1 | R1/8, R1/4 (option M: with M5 female thread) | ||
Fluid*2*6 | Air | ||
Indication precision*7) | ±0.03 MPa | ||
Pressure switch | Setting range*3*4 | 0.1 to 0.8 MPa | |
Hysteresis | 0.07 MPa or less | ||
Pointer error*5 | ±0.05 MPa (5 to 40°C) ±0.08 MPa (-5 to +60°C) (no freezing) | ||
Contact | With light: 1a (normally open) Without light: 1ab (normally open / normally closed) | ||
Wiring | Lead wire: 300 mm long | ||
Indicator light | AC | Neon light | |
DC | Light-emitting diode (LED) | ||
Clear cover | Part number: G46-00-00-3 | ||
Attachment: with cover ring assembly | C | Part number: 1305104-4A | |
C2 | Part number: 1305104-10A | ||
Weight (kg) | 0.12 |
*1: When mounting the pressure gauge, take care not to over-tighten. Excessive tightening will cause damage. Use pipe tape for sealing.
*2: Water is not an acceptable fluid. Before using other fluids, please contact the manufacturer's support center as there may be a corrosion problem.
*3: The set value of the pressure switch is indicated by the pointer (green). It is the point where the circuit between N.O. (white) and COM (black) is turned off during pressure decrease. To set the value, turn the needle in the clockwise direction to the correct value. When setting, if the desired set position has been passed, turn the needle in the counterclockwise direction back again beyond the desired value and then set it again.
*4: Make sure to provide a minimum difference of 0.1 MPa between the set pressure and the operating pressure (including the pressure drop). If the difference is smaller, it could lead to improper operation. See the manufacturer's catalog for details on how to set the setting needle. Note that the operating pressure should be the sum of the pressure of the setting needle error (±0.03 MPa), the hysteresis (0.07 MPa), and the display accuracy (±0.05 MPa) on the set pressure value, or the circuit between N.O. (white) and COM (black) may not turn ON while pressure is increasing.
*5: Maximum error value: Add the pressure gauge indicator error to the setting needle error.
*6: Take care to avoid freezing. This may result in a malfunction.
*7: The guaranteed temperature range is 23°C±5°C.
Circuit diagram without indicator light
Circuit diagram with indicator light (top: 110, 220 V AC, bottom: 24 V DC)
*The arrow in the diagram indicates the direction of the pressure increase. The light turns off at or above the set pressure and turns on when it is below the set pressure.
Model | Pressure range*1 | Indication unit | Port size | Note |
---|---|---|---|---|
MPa | ||||
GP46-10-01 to 02 (-Q) | 0 to 1.0 | MPa | R 1/8 R 1/4 | - |
GP46-10-01 to 02L2 | ||||
GP46-10-01 to 02L5 (-Q) |
*1: Do not apply pressure more than the maximum display pressure. This may result in a malfunction.
Model | Pressure range*1 | Indication unit | Port size | Note | |
---|---|---|---|---|---|
MPa | psi | ||||
GP46-10-01 to 02-X201 | 0 to 1.0 | - | MPa | R 1/8 R 1/4 | Lead wire length 3 m |
GP46-10-01 to 02L2-X201 | |||||
GP46-10-01 to 02L5-X201 |
*1: Do not apply pressure more than the maximum display pressure. This may result in a malfunction.
Load | Load resistance | ||
---|---|---|---|
Rated voltage | 30 V DC | 125 V AC | 250 V AC |
Operating current range | 0.01 to 0.5 A | 0.01 to 0.3 A | 0.01 to 0.2 A |
*The dimensions within ( ) are for port size R1⁄4
(Unit: mm)
GP46-10-01 to 02 (M) (L2, 5) dimensional drawing
(Unit: mm)
With cover ring assembly (for panel mount) GP46-10-01 to 02 (M) (L2, 5)-C dimensional drawing
Method 1
(1) Before setting the limit indicator and the (green) setting needle, turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then, remove by pulling it towards you.
Method 2
(2) Use a flat head screwdriver (with a 2.9‑mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate.
Method 3
(3) Before setting the setting needle, use a flat head screwdriver (with a 2.9‑mm blade width) to turn the setting screw and set the setting needle to the set pressure.
Turning the screw
Method 4
(4) After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case.
Référence pièce
|
---|
GP46-10-01ML5-Q |
Référence pièce |
Prix unitaire standard
| Quantité minimale de commande | Remise sur volume | Maximum Indicated Pressure | Connection screw | Option | Special Specification | Indication lamp addition symbol | Attachment | |
---|---|---|---|---|---|---|---|---|---|---|
55.68 € | 1 | 26 jours | 1,0 MPa | R 1⁄8 | Avec M5 (filetage femelle) | Marquage CE | Diode électroluminescente / 24VDC | Sans ensemble bague de couvercle |
Loading...
Shape | Filetage au dos |
---|
Vous vous trouvez sur la page de GP46, Manomètre avec détecteur (D.E. 42.5), le numéro d'article est le suivant: GP46-10-01ML5-Q.
Veuillez trouver plus de détails concernant les particularités et les dimensions sous le numéro d'article GP46-10-01ML5-Q.
Configurer
Propriétés de base
Type
Maximum Indicated Pressure
Connection screw
Option
Special Specification
Indication lamp addition symbol
Attachment
Filtrer par type de données CAO
Filtrer par jours d'expédition standard
Propriétés optionnelles
Référence pièce |
---|
GP46-10-01L2-C-Q |
GP46-10-01L2-Q |
GP46-10-01L5-C-Q |
GP46-10-02-C |
GP46-10-02-C-Q |
GP46-10-02-C-X201 |
Référence pièce | Prix unitaire standard | Quantité minimale de commande | Remise sur volume | Jour d'expédition standard ? | Maximum Indicated Pressure | Connection screw | Option | Special Specification | Indication lamp addition symbol | Attachment |
---|---|---|---|---|---|---|---|---|---|---|
57.98 € | 1 | 26 jours | 1,0 MPa | R 1⁄8 | - | Marquage CE | Avec néon / commun 100 à 220 V AC | Le couvercle transparent ne présente pas de saillie (le couvercle transparent ne peut pas être déposé) | ||
52.08 € | 1 | 26 jours | 1,0 MPa | R 1⁄8 | - | Marquage CE | Avec néon / commun 100 à 220 V AC | Sans ensemble bague de couvercle | ||
57.98 € | 1 | 28 jours | 1.0MPa | R 1⁄8 | - | Marquage CE | Diode électroluminescente / 24VDC | Le couvercle transparent ne présente pas de saillie (le couvercle transparent ne peut pas être déposé) | ||
58.03 € | 1 | 26 jours | 1,0 MPa | R1/4 | - | - | Sans témoin | Le couvercle transparent ne présente pas de saillie (le couvercle transparent ne peut pas être déposé) | ||
57.98 € | 1 | 26 jours | 1,0 MPa | R1/4 | - | Marquage CE | Sans témoin | Le couvercle transparent ne présente pas de saillie (le couvercle transparent ne peut pas être déposé) | ||
50.34 € | 1 | 26 jours | 1,0 MPa | R1/4 | - | Longueur de fil de sortie 3 m | Sans témoin | Le couvercle transparent ne présente pas de saillie (le couvercle transparent ne peut pas être déposé) |