IDFA100F / 125F / 150F, Sécheur d'air par réfrigération, grands formats (IDFA100F-40-RV)

IDFA100F / 125F / 150F, Sécheur d'air par réfrigération, grands formats IDFA100F-40-RV

Détails du produit:

Référence fabricant: IDFA100F-40-RV

Marque: SMC

Prix: 10,845.74

Délai de livraison: 68 jours


Données techniques:

Volume d'air traité: 14 333 l/min

Point de rosée de pression atmosphérique de l'air de sortie: 3 °C

Côté alimentation, type de connexion: [Rc (R)] R

Température de l'air côté port d'entrée: 35 °C

Côté alimentation, taille de filetage nominal du tuyau: 2


(i)Remarque

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2/MG types, etc., are already available.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

Référence pièce

Vous pouvez trouver ici le numéro
de référence lié au produit recherché.

IDFA100F-40-RV

Refrigerant R407C (HFC) IDFA100F/125F/150F Series For Use In Europe, Asia And Oceania Specifications

 IDFA100F/125F/150F Series external appearance

IDFA100F/125F/150F Series external appearance

JIS symbol

JIS symbol

Standard Specifications

Specifications Model
For use in Asia and Oceania For use in Europe
IDFA100F-38 IDFA125F-38 IDFA150F-38 IDFA100F-40 IDFA125F-40 IDFA150F-40
Operating range*3 Applicable fluid Compressed Air
Inlet air temperature (°C) 5 to 60
Inlet air pressure (MPa) 0.15 to 1.0
Ambient temperature (humidity) (°C) 2 to 45 (Relative humidity of 85% or less)
Rated conditions Air flow capacity
m3/h
Standard condition
(ANR)*1
960 1,210 1,500 860 1,100 1,340
Compressor
intake condition*2
1,000 1,255 1,560 875 1,119 1,363
Inlet air pressure (MPa) 0.7
Inlet air temperature (°C) 40 35
Ambient temperature (°C) 32 25
Outlet air pressure dew point (°C) 10 3
Power supply voltage Three-phase 380 V AC Three-phase 400 V AC
Electric specifications Power consumption (kW) 2.8 3.4 3.4 2.5 2.7 2.7
Operating current (A) 5.1 6.3 6.3 4.5 5.3 5.9
Applicable circuit breaker capacity*4 (A) 15
Heat discharge from condenser (kW) 7.5 9 11.5 7 8 10
Refrigerant R407C (HFC)
Refrigerant charge (kg) 1.25 1.36 2.0 1.25 1.36 1.8
Auto drain Float type (normally open)
Option V is a timer type solenoid valve
Port size R2 R2 1/2 DIN flange 80 R2 R2 1/2 DIN flange 80
Weight (kg) 245 270 350 245 270 350
Coating color Body panel: urban white 1
Base: urban gray 2
Compliant standards EC directive (with EU directive CE marking)

*1: Indicates the air flow capacity under ANR (atmospheric pressure 20°C, relative humidity 65%).
*2: Indicates the air flow capacity converted by the compressor intake condition (at 32°C, atmospheric pressure, relative humidity 75%).
*3: The operating range does not guarantee use at rated air flow capacity. If the operating conditions differ from the rating, select the model referring to "Model Selection" in the manufacturer's catalog.
*4: Products without option R do not come with a circuit breaker. Purchase an earth leakage breaker separately.

Dimensions

 

(Unit: mm)

 

IDFA100F/IDFA125F dimensional drawing

IDFA100F/IDFA125F dimensional drawing

Note) In addition to the overall length of the body, the filter mounting part (bracket) protrudes 10 mm.

 

(Unit: mm)

 

Model Piping connection port diameter A B C D E F G K L M N P
IDFA100F R2 670 1,120 1,276 267 460 1,375 335 20 712 107 700 752
IDFA125F R2 1/2 700 655 350 78 935

 

(Unit: mm)

 

IDFA150F dimensional drawing

IDFA150F dimensional drawing

Note) In addition to the overall length of the body, the filter mounting part (bracket) protrudes 10 mm.

 

(Unit: mm)

 

Model Piping connection port diameter A B C D E F G K L M N P
IDFA150F DIN flange 80 950 1,290 1,332 268 720 1,432 475 20 990 217 935 1,030

Structure Principle Diagram (Air/Refrigerant Circuit)

Structure principle diagram: IDFA100F, IDFA125F, IDFA150F

Structure principle diagram: IDFA100F, IDFA125F, IDFA150F

Humid, hot air coming into the air dryer is cooled down by a cooler re-heater (heat exchanger). Water condensed at this time is drained out automatically by the auto drain. Air separated from the water is heated in 2 stages by a re-heater (heat exchanger) in the cooler re-heater and a secondary heater to obtain the dried warm air, which goes through to the outlet side.

Secondary heater

By heat exchanging the compressed air removed from the drain and the refrigerant compressed by the refrigeration compressor, the following effects can be achieved:

  1. 1. Outlet air temperature is increased, securely preventing condensation at the output port.
  2. 2. Exhaust heat from condenser is reduced.
  3. 3. Reducing the exhaust heat from the condenser allows the dryer to save energy.

Precautions

  • *The images for this product are representative images.
  • *See the manufacturer's catalog for product information other than the above.
Référence pièce
IDFA100F-40-RV
Référence pièceRelatif à
Prix unitaire standard
Quantité minimale de commandeRemise sur volume
Jour
d'expédition standard
?
Volume d'air traité
(l/min)
Point de rosée de pression atmosphérique de l'air de sortie
(°C)
Côté alimentation, type de connexion Température de l'air côté port d'entrée
(°C)
Côté alimentation, taille de filetage nominal du tuyau Côté alimentation, désignation nominale de bride de tuyauterie Côté commande, types de connexions Côté commande, filetages nominaux de tuyau Côté commande, bride de tuyau nominale Standard size Power Supply Voltage Specifications Auto drain Copper Tube Anti-rust Processing Leakage Circuit Breaker
-

10,845.74 €

1 68 jours 14 3333[Rc (R)] R352-[Rc (R)] R2-100FTriphasé 400VAC (50Hz)AucunAvec purge auto de type électrovanne commandée par minuteurAucunOui

Loading...

  1. 1

Informations de base

Type Déshydrateur Méthode Type réfrigérant (spécifications de refroidissement par air) Forme Standard
Volume d'air traité [classification](l/min) Plus de 5000 Pression d'air côté port d'entrée(MPa) 0.7

Vous vous trouvez sur la page de IDFA100F / 125F / 150F, Sécheur d'air par réfrigération, grands formats, le numéro d'article est le suivant: IDFA100F-40-RV.
Veuillez trouver plus de détails concernant les particularités et les dimensions sous le numéro d'article IDFA100F-40-RV.

Variantes de ce produit

Référence pièce
IDFA100F-38-R
IDFA100F-40
IDFA100F-40-C
IDFA100F-40-V
IDFA125F-38
IDFA125F-40
Référence pièceRelatif àPrix unitaire standardQuantité minimale de commandeRemise sur volumeJour
d'expédition standard
?
Volume d'air traité
(l/min)
Point de rosée de pression atmosphérique de l'air de sortie
(°C)
Côté alimentation, type de connexion Température de l'air côté port d'entrée
(°C)
Côté alimentation, taille de filetage nominal du tuyau Côté alimentation, désignation nominale de bride de tuyauterie Côté commande, types de connexions Côté commande, filetages nominaux de tuyau Côté commande, bride de tuyau nominale Standard size Power Supply Voltage Specifications Auto drain Copper Tube Anti-rust Processing Leakage Circuit Breaker
-

12,096.01 €

1 26 jours 16,00010[Rc (R)] R402-[Rc (R)] R2-100FTriphasé 380 V AC (50 Hz)AucunAucunAucunOui

9,806.83 €

1 4 jours 14 3333[Rc (R)] R352-[Rc (R)] R2-100FTriphasé 400VAC (50Hz)AucunAucunAucunAucun

10,781.37 €

1 68 jours 14 3333[Rc (R)] R352-[Rc (R)] R2-100FTriphasé 400VAC (50Hz)AucunAucunOuiAucun

10,395.60 €

1 68 jours 14 3333[Rc (R)] R352-[Rc (R)] R2-100FTriphasé 400VAC (50Hz)AucunAvec purge auto de type électrovanne commandée par minuteurAucunAucun
-

13,322.39 €

1 68 jours 20,16710[Rc (R)] R40[Autre] 2 1/2-[Rc (R)] R[Autre] 2 1/2-125FTriphasé 380 V AC (50 Hz)AucunAucunAucunAucun

11,645.60 €

1 56 jours 18 3333[Rc (R)] R35[Autre] 2 1/2-[Rc (R)] R[Autre] 2 1/2-125FTriphasé 400VAC (50Hz)AucunAucunAucunAucun

Assistance technique