ITV209*, Convertisseur analogique du vide (Numéros de référence - Téléchargement CAO)

ITV209*, Convertisseur analogique du vide
  • En promotion jusqu’au 31/12/2024
A vacuum regulator with cable connections available in 2 directions.
[Features]
· Stepless control of air pressure proportional to an electrical signal.
· Compact and lightweight (integrated communications).
· Sensitivity: 0.2% F.S. or less.
· Linearity: ±1% F.S. or less / hysteresis: 0.5% F.S. or less.
· Grease-free specifications.
· IP65.
[Applications]
· For analog control of multistage control or electrostatic coating control.

(i)Remarque

  • Les images du produit peuvent être uniquement des images représentatives. Reportez-vous au catalogue du fabricant pour les détails de forme.

Référence pièce

Vous pouvez trouver ici le numéro
de référence lié au produit recherché.

Electronic Vacuum Regulator ITV2090/2091 Series Specifications

Electronic Vacuum Regulator ITV2090/2091 Series external appearance

Electronic Vacuum Regulator ITV2090/2091 Series external appearance

Model ITV2090 ITV2091
Minimum Supply Vacuum Pressure Note 1: Set pressure -13.3 kPa
Maximum Supply Vacuum Pressure -101 kPa
Set Pressure Range -1.3 to -80 kPa
Power Supply Voltage 24 V DC ±10% 12 to 15 V DC
Current Consumption Power supply voltage 24 V DC type: 0.12 A or less Note 7:
Power supply voltage 12 to 15 V DC type: 0.18 A or less
Input Signal Note 7: Current Type Note 2: 4 to 20 mA DC, 0 to 20 mA DC (sink type)
Voltage Type 0 to 5 V DC, 0 to 10 V DC
Preset Input 4 points (negative common), 16 points (no common polarity)
Digital Input 10 bit (parallel)
Input Impedance Current Type 250 Ω or less Note 3:
Voltage Type Approx. 6.5 k Ω
Preset Input Power supply voltage 24 V DC type: approx. 4.7 k Ω
Power supply voltage 12 V DC type: approx. 2.0 k Ω
Digital Input Approx. 4.7 k Ω
Output Signal Note 4:
(Monitor Output)
Analog Output 1 to 5 V DC (output impedance: approx. 1 kΩ)
4 to 20 mA DC (sink type) (output impedance: 250 Ω or less)
Output accuracy ±6% F.S. or less
Switch Output NPN open collector output: maximum 30 V, 80 mA
PNP open collector output: maximum 80 mA
Linearity ±1% F.S. or less
Hysteresis 0.5% F.S. or less
Repeatability ±0.5% F.S. or less
Sensitivity 0.2% F.S. or less
Temperature Characteristics ±0.12% F.S. / °C or less
Output Pressure Display Accuracy ±2% F.S. ±1 digit or less
Units kPa Note 5: minimum display: 1
Ambient And Fluid Temperature 0 to 50°C (no condensation)
Enclosure IP65
Weight Note 7: Note 8: 390 g

Note 1: For the minimum supply vacuum pressure, supply a vacuum pressure 13.3 kPa lower than the set maximum vacuum pressure.
Note 2: Two-wire type 4 to 20 mA DC is not available. Power supply voltage (24 V DC or 12 to 15 V DC) is required.
Note 3: Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is 350 Ω or less for an input current of 20 mA DC. When measuring ITV analog output from 1 to 5 V DC, if the load impedance is less than 100 kΩ, an analog monitor output accuracy of within ±6% (full span) may not be achievable. If an accuracy within ±6% is required, contact the manufacturer for further assistance. Output pressure remains unaffected.
Note 4: Select either analog output or switch output. When switch output is selected, select either NPN output or PNP output. Note that the preset input type does not have an output signal function.
Note 5: Contact the manufacturer for other pressure unit displays.
Note 6: The above characteristics are confined to the static state. When air is consumed on the output side, the pressure may fluctuate.
Note 7: Refer to the table below for communication specifications.
Note 8: Add 50 g for the digital input type, and 70 g for the 16-point preset input type.

 
Wiring diagram

Wiring diagram

Example with analog control for multistage control

Example with analog control for multistage control

Example with electrostatic coating control

Example with electrostatic coating control

Communication Specifications (CC, DE, PR, RC)

Model ITV□0□0-CC□□ ITV□0□0-DE□□ ITV□0□0-PR□□ ITV□0□0-RC□□
Protocol Name CC-Link DeviceNet PROFIBUS DP RS-232C
Version Note 1: Ver 1.10 Volume 1 (Edition 3.8)
Volume 3 (Edition 1.5)
DP-V0 -
Communication Speed 156 k / 625 k
2.5 M / 5 M / 10 M bps
125 k / 250 k / 500 k bps 9.6 k / 19.2 k / 45.45 k
93.75 k / 187.5 k / 500 k
1.5 M / 3 M / 6 M / 12 M bps
9.6 kbps
Configuration File Note 2: - EDS GSD -
I/O Occupation Area
(Input/Output Data)
4 word / 4 word, 32 bit / 32 bit
(Per station, remote device station)
16 bit / 16 bit 16 bit / 16 bit -
Communication Data Resolution 12 bit (4,096 resolution) 12 bit (4,096 resolution) 12 bit (4,096 resolution) 10 bit (1,024 resolution)
Fail Safe HOLD Note 3: / CLEAR
(Switch setting)
HOLD/CLEAR
(Switch setting)
CLEAR HOLD
Electric Insulation Note 4: Insulation Insulation Insulation Non-insulated
Terminating Resistor Built into the product (switch setting) Not built into the product Built into the product (switch setting) -
Current Consumption 0.16 A or less 0.14 A or less 0.16 A or less 0.12 A or less
Weight ITV2090 470 460 490 460

Note 1: Note that version information is subject to change.
Note 2: Check each file from the product documentation and instruction manual.
Note 3: The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data.
Note 4: Indicates the insulation between the electrical signal of the communication system and the ITV power supply.

Drawing

 

(Unit: mm)

 

ITV209□ flat bracket dimensional drawing

ITV209□ flat bracket dimensional drawing

L-bracket dimensional drawing

L-bracket dimensional drawing

Right angle type (4-core) / 3‑m cable connector dimensional drawing

Right angle type (4-core) / 3‑m cable connector dimensional drawing

Straight type (4-core) / 3‑m cable connector dimensional drawing

Straight type (4-core) / 3‑m cable connector dimensional drawing

Note: The cable connector cannot be rotated. Do not try to rotate it.

Operating Principles

ITV2090/2091 Series operating principle diagram

ITV2090/2091 Series operating principle diagram

When the input signal rises, the vacuum pressure solenoid valve (1) turns ON and the atmospheric pressure solenoid valve (2) turns OFF.
Therefore, pressure in the pilot chamber (3) becomes negative pressure through VAC. and the pilot chamber, which operates on the upper portion of the diaphragm (4).
As a result, the vacuum pressure valve (5) linked to the diaphragm (4) opens, and the set pressure becomes negative pressure through VAC. and OUT.
This negative pressure feeds back to the control circuit (8) via the pressure sensor (7).
Here, pressure corrections continue until the vacuum pressure becomes proportional to the input signal, thus supplying vacuum pressure that is consistently proportional to the input signal.

ITV2090/2091 Series block diagram

ITV2090/2091 Series block diagram

Notes

  • Do not connect a lubricator on the supply side of the product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of the product.
  • If power supply is shut off while pressure is being applied, pressure will be retained on the output side. However, this output pressure is held only temporarily and is not guaranteed. If exhausting of this pressure is desired, shut off the power after reducing the set pressure and discharge the air using a residual pressure exhaust valve, etc.
  • If power to the product is cut off due to something such as a power failure while it is in a controlled state, output pressure will be retained temporarily. Handle carefully when operating with output pressure released to the atmosphere, as air will continue to flow out.
  • If supply pressure to the product is interrupted while the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Shut off the power supply as well when the supply pressure is shut off as failure to do so may cause the lifespan of the product to shorten.
  • *Refer to the manufacturer's catalog for product information not detailed above.
  • *The product images may be representative images only.
Référence pièce
ITV2091-31F2CL5
ITV2091-31F2L5
ITV2091-31F2N5
ITV2091-31F2S5
ITV2091-212BS5
ITV2091-212S5
ITV2091-312BL5
ITV2091-312CL5
ITV2091-312L5
ITV2091-402S5
Référence pièceRelatif à
Prix unitaire standard
Quantité minimale de commandeRemise sur volume
Jour
d'expédition standard
?
Côté alimentation, type de connexion Côté commande, types de connexions Signal d'entrée Connecteur de câble Signal de communication Sortie de moniteur Support Tension d'alimentation électrique
-

533.47 €

1 26 jours GG0 à 10VDCType à angle droit 3mType de tension 0 à 10VDCSortie analogique 1 à 5VDCSupport en L12 à 15 V DC
-

530.00 €

1 26 jours GG0 à 10VDCType à angle droit 3mType de tension 0 à 10VDCSortie analogique 1 à 5VDCSans support12 à 15 V DC
-

504.71 €

1 26 jours GG0 à 10VDCSans connecteur de câbleType de tension 0 à 10VDCSortie analogique 1 à 5VDCSans support12 à 15 V DC
-

530.00 €

1 26 jours GG0 à 10VDCType droit 3 mType de tension 0 à 10VDCSortie analogique 1 à 5VDCSans support12 à 15 V DC
-

533.47 €

1 26 jours Rc (R)Rc (R)0 à 5VDCType droit 3 mType de tension 0 à 5 V DCSortie analogique 1 à 5VDCSupport plat12 à 15 V DC
-

530.00 €

1 26 jours Rc (R)Rc (R)0 à 5VDCType droit 3 mType de tension 0 à 5 V DCSortie analogique 1 à 5VDCSans support12 à 15 V DC
-

533.47 €

1 26 jours Rc (R)Rc (R)0 à 10VDCType à angle droit 3mType de tension 0 à 10VDCSortie analogique 1 à 5VDCSupport plat12 à 15 V DC
-

533.47 €

1 26 jours Rc (R)Rc (R)0 à 10VDCType à angle droit 3mType de tension 0 à 10VDCSortie analogique 1 à 5VDCSupport en L12 à 15 V DC
-

530.00 €

1 26 jours Rc (R)Rc (R)0 à 10VDCType à angle droit 3mType de tension 0 à 10VDCSortie analogique 1 à 5VDCSans support12 à 15 V DC
-

535.97 €

1 26 jours Rc (R)Rc (R)Entrée prérégléeType droit 3 mEntrée préréglée 4 pointsNonSans support12 à 15 V DC

Loading...

Informations de base

Type Régulateur de vide électronique Méthode de contrôle Pilote interne Forme Standard
Supply Side, Nominal Designation of Piping Thread 1/4 Côté commande, filetages nominaux de tuyau 1/4 Plage de pression de réglage(kPa) -1.3::-80

Assistance technique