VZ100, Electrodistributeur 3 / 2, joint élastique, millimètres (Numéros de référence)

VZ100, Electrodistributeur 3 / 2, joint élastique, millimètres
SMC Solenoid Valve.
[Features]
· Low power consumption: 1.8 W DC
· Can also be used for vacuum applications up to -100 kPa

(i)Remarque

  • Les images des produits peuvent être représentatives. Reportez-vous au catalogue du fabricant pour plus de détails.

Référence pièce

Vous pouvez trouver ici le numéro
de référence lié au produit recherché.

VZ110-2D-M5-Q

Rubber Seal 3-Port / Direct Connection Type VZ100 Series Specifications

VZ100 Series external appearance

VZ100 Series external appearance

VZ100 Series body ported type external appearance

VZ100 Series body ported type external appearance

Type of actuation: JIS symbols for normally closed

Type of actuation: JIS symbols for normally closed

Type of actuation: JIS symbols for normally open

Type of actuation: JIS symbols for normally open

*R port on VZ120 is a supply port.

Usable Fluids Air
Operating Pressure Range See table below
Ambient and fluid temperature (°C) -10 to 50 (no freezing)
*1Response time (ms) 15 or less
Maximum Operating Frequency Hz 15
Flow Rate Characteristics See table below
Manual Operation Non-locking, push type
Lubrication Not required
Mounting Orientation Free
*2: Impact Resistance / Vibration Resistance: m/s2 300/50
Enclosure Dust-proof

*1: Based on JIS B 8374-1981 dynamic performance test. (Coil temperature of 20°C, at rated voltage, with no surge voltage suppressor)
*2: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunction occurred in 1 sweep test between 45 and 1,000 Hz. The test was performed in both energized and de-energized states in the axial and right angle directions of the main valve/armature. (Initial value)

Solenoid Specifications

Electrical Entry Grommet (G)/(H), L plug connector (L), M plug connector (M), DIN terminal (D)
Coil rated voltage (V) AC 50/60 Hz 100, 200, 110, 220
DC 24, 12
Allowable voltage fluctuation (%) -15% to +10% of rated voltage
*Power consumption (W)
[Current value (mA)]
DC 1.8 (with indicator light: 2.1) [24 V DC: 75 (with indicator light: 87.5)]
*Apparent power (VA)
[Current value (mA)]
AC Starting 4.5/50 Hz, 4.2/60 Hz
[100 V AC: 45/50 Hz, 42/60 Hz]
[200 V AC: 22.5 / 50 Hz, 21 / 60 Hz]
Holding 3.5 / 50 Hz, 3 / 60 Hz
[100 V AC: 35 / 50 Hz, 30 / 60 Hz]
[200 V AC: 17.5 / 50 Hz, 15 / 60 Hz]
Surge Voltage Suppressor DC: Diode, AC: ZNR
Indicator Light DC: LED (red), AC: Neon bulb

*At rated voltage.

Operating pressure range and weight

Valve Model Numbers Switching Method Operating Pressure Range Vacuum specification (MPa) Piping connection port diameter *Weight
g
MPa 1 (P) port 3 (R) port
Body Ported Types VZ110 N.C. 0 to 0.7 -27 kPa to 0.6 -100 kPa to 0 M5 ×; 0.8 70
VZ120 N.O. 0 to 0.5 -100 kPa to 0 -100 kPa to 0.4

*Weight for grommet type.

Flow Rate Characteristics Table

Valve Model Numbers Switching Method Piping connection port diameter Flow Rate Characteristics
Supply side
[N.C.: 1→2 (P→A)]
[N.O.: 3→2 (R→A)]
Exhaust side
[N.C.: 2→3 (A→R)]
[N.O.: 2→1 (A→P)]
C (dm3 / [s·bar]) b Cv C (dm3 / [s·bar]) b Cv
Body Ported Types VZ110 N.C. M5 ×; 0.8 0.11 0.026 0.023 0.19 0.071 0.042
VZ120 N.O. 0.19 0.071 0.042 0.13 0.18 0.031

Structure Drawing

VZ110 (N.C. type) structure drawing / JIS symbols

VZ110 (N.C. type) structure drawing / JIS symbols

VZ120 (N.O. type) structure drawing / JIS symbols

VZ120 (N.O. type) structure drawing / JIS symbols

Number Part name Material Note
(1) Body ZDC Platinum silver
(2) Push Rod Resin -
(3) EXH poppet NBR -
(4) N.C. Back-up spring SUS -
N.O. Poppet Spring
(5) Solenoid assembly Epoxy
SUS
VZ110
(6) Solenoid assembly Epoxy
SUS
VZ120
(7) O-ring NBR VZ300
VZ500
Common with series

Outline dimensional drawing

Body Ported Types

 

(Unit: mm)

 

Grommet (G) (H) VZ1□0-□G/H-M5 (-F) dimensional drawings

Grommet (G) (H) VZ1□0-□G/H-M5 (-F) dimensional drawings

 

(Unit: mm)

 

L plug connector (L) VZ1□0-□L□-M5 dimensional drawing

L plug connector (L) VZ1□0-□L□-M5 dimensional drawing

 

(Unit: mm)

 

M plug connector (M) VZ1□0-□M□-M5 dimensional drawing

M plug connector (M) VZ1□0-□M□-M5 dimensional drawing

 

(Unit: mm)

 

DIN terminal (D) VZ1□0-□D□-M5 dimensional drawing

DIN terminal (D) VZ1□0-□D□-M5 dimensional drawing

  • *Numbers inside boxes indicate with models indicator light / surge voltage suppressor.
  • *See the manufacturer's catalog for information other than the above.
Référence pièce
VZ110-2D-M5-Q
Référence pièce
Prix unitaire standard
Quantité minimale de commandeRemise sur volume
Jour
d'expédition standard
?
Type à commutation Tension Valeur CV Pression nominale
(MPa)
Entrée électrique du fil de sortie Témoin / Suppresseur de surtension Option

51.44 €

1 26 jours 2 positions, normalement fermé200VAC0.0230 à 0,7Borne DIN avec connecteurAucunAucun

Loading...

  1. 1

Informations de base

Type Électrovannes Application Utilisation unique Nombre de ports Vanne à 3 ports
Sens du montage Direct Caractéristiques Standard / Compatible avec un vide primaire / Sans lubrification / Faible courant Nombre de solénoïdes Simple
État à la mise hors tension Reprise automatique (retour de ressort) Type à port de tuyau M Filetage nominal de tuyauterie M5
Tuyauterie Tuyauterie directe Type d'entraînement Clapet à mouvement linéaire Type de joint Joint souple
Interrupteur manuel Non bloquant Conformité CE Oui

Vous vous trouvez sur la page de VZ100, Electrodistributeur 3 / 2, joint élastique, millimètres, le numéro d'article est le suivant: VZ110-2D-M5-Q.
Veuillez trouver plus de détails concernant les particularités et les dimensions sous le numéro d'article VZ110-2D-M5-Q.

Variantes de ce produit

Référence pièce
VZ110-1D-M5-Q
VZ110-1DO-M5-Q
VZ110-3D-M5-Q
VZ110-3DO-M5-Q
VZ110-3DZ-M5-Q
VZ110-4D-M5-F-Q
Référence piècePrix unitaire standardQuantité minimale de commandeRemise sur volumeJour
d'expédition standard
?
Type à commutation Tension Valeur CV Pression nominale
(MPa)
Entrée électrique du fil de sortie Témoin / Suppresseur de surtension Option

48.89 €

1 26 jours 2 positions, normalement fermé100VAC0.0230 à 0,7Borne DIN avec connecteurAucunAucun

46.40 €

1 26 jours 2 positions, normalement fermé100VAC0.0230 à 0,7Borne DIN sans connecteur / Borne DIN, sans connecteurAucunAucun

51.44 €

1 4 jours 2 positions, normalement fermé110VAC0.0230 à 0,7Borne DIN, avec connecteurAucunAucun

49.02 €

1 26 jours 2 positions, normalement fermé110VAC0.0230 à 0,7Borne DIN sans connecteur / Borne DIN, sans connecteurAucunAucun

59.82 €

1 26 jours 2 positions, normalement fermé110VAC0.0230 à 0,7Borne DIN, avec connecteurAvec témoin et suppresseur de surtensionAucun

53.18 €

1 26 jours 2 positions, normalement fermé220VAC0.0230 à 0,7Borne DIN avec connecteurAucunAvec support de pied

Assistance technique