Référence fabricant: IZD10-110
Marque: SMC
Prix: 431.27 €
Délai de livraison: 4 jours
Potentiels mesurés: ±0.4kV (plage de détection à 25mm)
Référence pièce
Vous pouvez trouver ici le numéro
de référence lié au produit recherché.
IZD10-110
Electrostatic Sensor Type | IZD10-110 | IZD10-510 |
---|---|---|
Potential Measurement | ±0.4 kV (detection range at 25 mm)* | ±20 kV (detection range at 50 mm)* |
Output Voltage | 1 to 5 V (Output impedance: Approx. 100Ω) | |
Effective Detection Distance | 10 to 50 mm | 25 to 75 mm |
Linearity | ±5% F.S. (0 to 50°C, at detection distance of 25 mm) | ±5%F.S. (0 to 50°C, at detection distance of 50 mm) |
Output Delay Time | 100 ms or less | |
Power Supply Voltage | 21.6 to 26.4 V DC (Within 24 V DC ±10%) | |
Current Consumption | 40 mA or less | |
Ambient Operating Temperature | 0 to 50°C | |
Ambient Humidity | 35 to 85% Rh (with no condensation) | |
Material | Head case: ABS, Amplifier case: ABS | |
Vibration Resistance | Durability 50 Hz, Amplitude 1 mm, X, Y, Z: 2 hours each | |
Impact Resistance | 100 m/s2 | |
Weight | 185 g (including cable weight) | |
Compliance with EN Standards | Protective Class: Class III (EN60950-1) Pollution Degree 3 CE Marking: Low voltage directive: 2006/95/EC Only when connected to a SELV-type external circuit | |
EMC Directive | 2004/108/EC | |
UL Standard | UL508 |
*The measured potential and output voltage varies depending on the detection distance. For details of the relationship between measured potentials and output voltages according to detection distance, refer to the "Output Signal" graphs in the Technical Data section of the catalog.
Connect the lead wires according to the connection circuit and wiring table.
IZD10 Series connection circuit
Lead Wire Coating Color | Description | Function |
---|---|---|
Brown | DC (+) | Power supply 24 V DC |
Blue | DC (-) | Power Supply 0 V |
White | Sensor output | Analog output for 1 to 5 V |
(Unit: mm)
IZD10-110/IZD10-510 dimensional drawing 1
(Unit: mm)
IZD10-110/IZD10-510 dimensional drawing 2
(Unit: mm)
IZD10-110/IZD10-510 dimensional drawing 3
When measuring the potential of a charged object with an electrostatic sensor, the relationship between the electrostatic potential being measured and the output voltage varies depending on the sensor's installation distance. The relationship between the electrostatic sensor's output voltage and the detected electrostatic potential depending on the installation distance is as shown in the figure below. (The installation distance in the figure refers to the distance between the object being measured and the electrostatic sensor.)
IZD10-110 electrostatic potential graph
IZD10-510 electrostatic potential graph
IZD10 Series detection range
IZD10 Series part names
Installation Range (mm) | Detection Range (mm) |
---|---|
10 | 45 |
20 | 85 |
25 | 100 |
30 | 120 |
40 | 150 |
50 | 180 |
Installation Range (mm) | Detection Range (mm) |
---|---|
25 | 100 |
30 | 120 |
40 | 150 |
50 | 180 |
60 | 205 |
70 | 225 |
75 | 235 |
Référence pièce
|
---|
IZD10-110 |
Référence pièce |
Prix unitaire standard
| Quantité minimale de commande | Remise sur volume | Potentiels mesurés | |
---|---|---|---|---|---|
431.27 € | 1 | 4 jours | ±0.4kV (plage de détection à 25mm) |
Loading...
Type | Dispositifs de mesure antistatiques | Indicateurs | Non fourni | Fonction supplémentaire | Non fourni |
---|---|---|---|---|---|
Fonction de réglage de l'équilibre ionique | Non fourni | Source d'alimentation | 24VDC |
Vous vous trouvez sur la page de IZD10, Capteur électrostatique, le numéro d'article est le suivant: IZD10-110.
Veuillez trouver plus de détails concernant les particularités et les dimensions sous le numéro d'article IZD10-110.
Configurer
Propriétés de base
Type
Potentiels mesurés
Filtrer par type de données CAO
Filtrer par jours d'expédition standard
Propriétés optionnelles
Référence pièce |
---|
IZD10-510 |
Référence pièce | Prix unitaire standard | Quantité minimale de commande | Remise sur volume | Jour d'expédition standard ? | Potentiels mesurés |
---|---|---|---|---|---|
431.27 € | 1 | 4 jours | ±20 kV (plage de détection à 50 mm) |