IDFA3~75E, Sécheur d'air par réfrigération (IDFA37E-23-CK)

IDFA3~75E, Sécheur d'air par réfrigération IDFA37E-23-CK

Détails du produit:

Référence fabricant: IDFA37E-23-CK

Marque: SMC

Prix: 3,906.27

Délai de livraison: 26 jours


Données techniques:

Volume d'air traité [classification]: Plus de 5000 l/min

Volume d'air traité: 4 550 / 5 783 / 6 366 l/min

Côté alimentation, taille de filetage nominal du tuyau: 1 1/2

Côté commande, filetages nominaux de tuyau: 1 1/2

Standard size: 37E


(i)Remarque

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2/MG types, etc., are already available.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

Référence pièce

Vous pouvez trouver ici le numéro
de référence lié au produit recherché.

IDFA37E-23-CK

Refrigerant R407C (HFC) Series IDFA□E Specifications

JIS symbol

JIS symbol

Size

  • 22E
  • 37E
  • 55E
  • 75E

Standard Specifications

Specifications Model
Standard-temperature air inlet
IDFA22E IDFA37E IDFA55E IDFA75E
Operating range*3 Applicable fluid Compressed Air
Inlet air temperature (°C) 5 to 50
Inlet air pressure (MPa) 0.15 to 1.0
Ambient temperature (humidity) (°C) 2 to 40 (Relative humidity of 85% or less)
*4 Air flow capacity m3/h Standard condition
(ANR)*1
Outlet air pressure dew point 3°C 182 273 390 660
Outlet air pressure dew point 7°C 231 347 432 720
Outlet air pressure dew point 10°C 254 382 510 822
Compressor
intake condition*2
Outlet air pressure dew point 3°C 189 284 405 686
Outlet air pressure dew point 7°C 240 361 449 748
Outlet air pressure dew point 10°C 264 397 530 854
Inlet air pressure (MPa) 0.7
Inlet air temperature (°C) 35
Ambient temperature (°C) 25
Power supply voltage Single-phase 230 V AC (Voltage fluctuation ±10%) 50 Hz
Electric specifications Power consumption*6 (W) 760 1,390 1,700
Operating current*6 (A) 4.3 6.1 7.9
Applicable circuit breaker capacity*5 (A) 10 20
Condenser Air-cooled
Refrigerant R407C (HFC)
Refrigerant charge (kg) 0.42 0.73 0.55 0.67
Port size R1 R1 1/2 R2
Accessories -
Weight (kg) 54 62 100 116

*1: ANR is the value at 20°C, atmospheric pressure and relative humidity 65%.
*2: Indicates the air flow capacity converted by the compressor intake condition (at 32°C, atmospheric pressure, relative humidity 75%).
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to "Model Selection" in the manufacturer's catalog.
*5: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
*6: These are characteristic values under rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*7: When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns.

Dimensions

 

(Unit: mm)

 

Dimensional drawing: IDFA22E/IDFA37E

Dimensional drawing: IDFA22E/IDFA37E

 

(Unit: mm)

 

Model Piping connection port diameter A B C D E F G K L M N P
IDFA22E R1 290 775 623 134 405 698 93 13 25 85 600 340
IDFA37E R11/2 855 680

 

(Unit: mm)

 

IDFA55/IDFA75E dimensional drawing

IDFA55/IDFA75E dimensional drawing

 

(Unit: mm)

 

Model Piping connection port diameter A B C D E F G K L M N P Q R
IDFA55E R2 470 855 800 (128) (273) (868) (110) 13 500 75 700 526 (110) 519
IDFA75E 900 (968)

Structure Principle Diagram (Air/Refrigerant Circuit)

Structure Principle Diagram

Structure Principle Diagram

Humid, hot air coming into the air dryer is cooled down by a cooler re-heater (heat exchanger). Water condensed at this time will be drained out automatically by the auto drain. Air separated from the water is heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side.

Precautions

  • *The images for this product are representative images.
  • *See the manufacturer's catalog for product information other than the above.
Référence pièce
IDFA37E-23-CK
Référence pièce
Prix unitaire standard
Quantité minimale de commandeRemise sur volume
Jour
d'expédition standard
?
Volume d'air traité [classification]
(l/min)
Volume d'air traité
(l/min)
Côté alimentation, taille de filetage nominal du tuyau Côté commande, filetages nominaux de tuyau Standard size Auto drain Copper Tube Anti-rust Processing For medium pressure air Leakage Circuit Breaker Operation, Terminal block for abnormal signal takeout

3,906.27 €

1 26 jours Plus de 50004 550 / 5 783 / 6 3661 1/21 1/237EAucunOuiPour l'air à moyenne pression (étui pour purge auto : étui métallique avec jauge de niveau)AucunAucun

Loading...

  1. 1

Informations de base

Méthode Type réfrigérant (spécifications de refroidissement par air) Forme Standard Point de rosée de pression atmosphérique de l'air de sortie(°C) 10 / 3 / 7
Côté alimentation, type de connexion R Température de l'air côté port d'entrée(°C) 35 Pression d'air côté port d'entrée(MPa) 0.7
Côté commande, types de connexions R Power Supply Voltage Monophasé : 230VAC (50Hz) Plaque signalétique chinoise, manuel d'utilisation chinois Aucun

Vous vous trouvez sur la page de IDFA3~75E, Sécheur d'air par réfrigération, le numéro d'article est le suivant: IDFA37E-23-CK.
Veuillez trouver plus de détails concernant les particularités et les dimensions sous le numéro d'article IDFA37E-23-CK.

Variantes de ce produit

Référence pièce
IDFA22E-23-L
IDFA37E-23-C
IDFA37E-23-CL
IDFA37E-23-CLR
IDFA37E-23-CRT
IDFA37E-23-CT
Référence piècePrix unitaire standardQuantité minimale de commandeRemise sur volumeJour
d'expédition standard
?
Volume d'air traité [classification]
(l/min)
Volume d'air traité
(l/min)
Côté alimentation, taille de filetage nominal du tuyau Côté commande, filetages nominaux de tuyau Standard size Auto drain Copper Tube Anti-rust Processing For medium pressure air Leakage Circuit Breaker Operation, Terminal block for abnormal signal takeout

3,009.41 €

1 39 jours Jusqu'à 50004 233 / 3 850 / 3 0331122EAvec purge auto pour usage intensifAucunAucunAucunAucun

3,748.79 €

1 26 jours Plus de 50005 783 / 4 550 / 6 3661 1/21 1/237EAucunOuiAucunAucunAucun

4,142.64 €

1 26 jours Plus de 50005 783 / 4 550 / 6 3661 1/21 1/237EAvec purge auto pour usage intensifOuiAucunAucunAucun

4,723.37 €

1 98 jours Plus de 50005 783 / 4 550 / 6 3661 1/21 1/237EAvec purge auto pour usage intensifOuiAucunOuiAucun

4,893.20 €

1 26 jours Plus de 50005 783 / 4 550 / 6 3661 1/21 1/237EAucunOuiAucunOuiOui

4,312.47 €

1 26 jours Plus de 50005 783 / 4 550 / 6 3661 1/21 1/237EAucunOuiAucunAucunOui

Assistance technique