Données techniques:

Côté alimentation, type de connexion: Rc

Côté alimentation, diam. de connexion: 1/8

Côté commande, types de connexions: Rc

Jauge de pression: [Non fourni] N/A

Size of Body: 1 000


(i)Remarque

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
    Click here for a quotation or to make an order if you have a model number.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2, MG types, etc., are already available. Click here to check.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See the catalog for specification details.
  • Product images may be representative images. Refer to the catalog for details.

Référence pièce

Vous pouvez trouver ici le numéro
de référence lié au produit recherché.

ARM1000-1A1-01

ARM1000/2000 Series Manifold Regulator Specifications

ARM2000-4B2 external appearance

ARM2000-4B2 external appearance

ARM2000-4A2-01G external appearance

ARM2000-4A2-01G external appearance

Common IN (left) / individual IN (right) JIS symbols

Common IN (left) / individual IN (right) JIS symbols

Conceptual diagram of connection variants

Conceptual diagram of connection variants

Ambient and fluid temperature -5 to +60°C (no freezing)
Fluid Air
Cracking pressure (valve) 0.02 MPa
Structure Relieving type

Port Size / Weight

Model Piping specifications Connection port size Weight (g)
IN side OUT side Total weight (n: stations) Regulator (except manifold)
ARM1000 Common IN 1/8 1/8 (80 ×; n) + 23 57
Individual IN 1/8 1/8 (79 ×; n) +25
ARM2000 Common IN 1/4 1/8 (188 ×; n) +43 136
Individual IN 1/8 1/8 (187 ×; n) +45

Diagram (Individual IN)

Individual IN Diagram

Individual IN Diagram

Number Part name Material Note
1 Main body Die-cast aluminum Chromate treatment
2 Manifolds Aluminum alloy Chromate treatment
3 Valve guide Brass -
4 Piston Brass -
5 Pressure regulator spring Steel wire Zinc chromate
6 Adjusting screw Structural steel Electroless nickel plating
Number Part name Material
7 Valve Brass, HNBR
8 Valve spring Stainless steel
9 Valve retainer Polyacetal
10 O-ring NBR
11 O-ring NBR

Setting

  • 1.Make sure to check the inlet pressure before setting the outlet pressure. Turning the pressure adjustment handle clockwise increases the outlet pressure and turning it counterclockwise decreases the pressure. (To set the pressure, do so in the direction of pressure)
  • 2.The outlet pressure range must be 85% or less than the inlet pressure.

Flow Characteristics (Representative Values)

Conditions: inlet pressure = 0.7 MPa

ARM1000 flow rate characteristics graph

ARM1000 flow rate characteristics graph

ARM2000 flow rate characteristics graph

ARM2000 flow rate characteristics graph

Pressure Characteristics (Representative Values)

Conditions (initial settings): inlet pressure 0.7 MPa, outlet pressure 0.2 MPa, flow rate 10 L/min (ANR)

ARM1000 pressure characteristics graph

ARM1000 pressure characteristics graph

ARM2000 pressure characteristics graph

ARM2000 pressure characteristics graph

Dimensions

 

(Unit: mm)

 

ARM1000/2000 Series dimensional drawing

ARM1000/2000 Series dimensional drawing

External Dimensions Table

 

(Unit: mm)

 

Model Symbol
A B C D E F G H J K M P Q R
ARM1000 4.5 25 34 21 18 56 16 9 18 19 52 9 11.5 4.8
ARM2000 4.5 34.5 43 28 27 70 20 11.5 24 28 66 11.5 16.5 4.8

Dimensions by the Number of Stations

 

(Unit: mm)

 

Model Symbol Manifold stations (n)
1 2 3 4 5 6 7 8 9 10
ARM1000 L1 36 55 74 93 112 131 150 169 188 207
L2 27 46 65 84 103 122 141 160 179 198
ARM2000 L1 48 76 104 132 160 188 216 244 272 300
L2 39 67 95 123 151 179 207 235 263 291

Precautions

Mounting/Adjustment

  • *In the case of the common IN type, supply pressure from the two IN ports from both ends. Failure to observe this procedure could lead to an excessive pressure drop.
  • *Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.
    Lock operating method
    Loosen the handle locking nut to release the lock, and tighten it to lock it.
  • *The attached reverse flow mechanism is placed between the electromagnetic valve and actuator and can be used as a check regulator.

Maintenance

  • *Make sure to perform a periodic inspection of the pressure gauge when it is used by installing it between a solenoid valve and an actuator, etc. Because of the possibility of creating sudden pressure fluctuations, the durability of the product could be shortened. Under certain circumstances, the use of an electronic type pressure gauge is recommended.

Other precautions

  • *Be sure to read the safety precautions as well as the common precautions in the manufacturer's catalog before use.
  • *The images for this product are representative images. *The product shown may differ from the actual product.
  • *See the manufacturer's catalog for information other than the above.
Référence pièce
ARM1000-1A1-01
Référence pièceRelatif à
Prix unitaire standard
Quantité minimale de commandeRemise sur volume
Jour
d'expédition standard
?
Côté alimentation, type de connexion Côté alimentation, diam. de connexion Côté commande, types de connexions Jauge de pression Size of Body Set Pressure Connected Number Piping Specification

22.48 €

1 26 jours Rc1/8Rc[Non fourni] N/A1 0000.05 à 0.7MPa1 posteENTRÉE : commune, SORTIE : côté collecteur

Loading...

  1. 1

Informations de base

Régulateur, soupape de suralimentation Régulateur Type de régulateur En forme de distributeur Fluide applicable Air
Forme Standard Environnement de fonctionnement Standard Mécanisme d'échappement Décharge
Fonction contre-courant Disponible Plage de pression de fonctionnement(MPa) nul::0.8 Côté commande, diamètre de connexion 1/8

Vous vous trouvez sur la page de ARM1000 / 2000, Série de régulateurs sur embase, le numéro d'article est le suivant: ARM1000-1A1-01.
Veuillez trouver plus de détails concernant les particularités et les dimensions sous le numéro d'article ARM1000-1A1-01.

Variantes de ce produit

Référence pièce
ARM1000-10B1-01
ARM1000-10B1-01G
ARM1000-10B2-01
ARM1000-1A1-01G
ARM1000-1B1-01
ARM1000-1B1-01-1
Référence pièceRelatif àPrix unitaire standardQuantité minimale de commandeRemise sur volumeJour
d'expédition standard
?
Côté alimentation, type de connexion Côté alimentation, diam. de connexion Côté commande, types de connexions Jauge de pression Size of Body Set Pressure Connected Number Piping Specification
-

245.74 €

1 26 jours Rc1/8Rc[Non fourni] N/A1 0000.05 à 0.7MPa10 postesENTRÉE : individuelle, SORTIE : côté collecteur
-

324.27 €

1 26 jours Rc1/8Rc[Avec jauge de pression] Avec manomètre1 0000.05 à 0.7MPa10 postesENTRÉE : individuelle, SORTIE : côté collecteur
-

245.74 €

1 26 jours Rc1/8Rc[Non fourni] N/A1 0000.05 à 0.7MPa10 postesIN: individuel, OUT : côté du corps
-

30.39 €

1 26 jours Rc1/8Rc[Avec jauge de pression] Avec manomètre1 0000.05 à 0.7MPa1 posteENTRÉE : commune, SORTIE : côté collecteur

23.63 €

1 4 jours Rc1/8Rc[Non fourni] N/A1 0000.05 à 0.7MPa1 posteENTRÉE : individuelle, SORTIE : côté collecteur
-

27.18 €

1 26 jours Rc1/8Rc[Non fourni] N/A1 0000.05 à 0.2MPa1 posteENTRÉE : individuelle, SORTIE : côté collecteur

Assistance technique